Honda Accord: Rocker Arm Oil Pressure Switch
Removal/Installation - VTEC/VTC - Fuel and Emissions - Honda Accord MK8 2008-2012 Service ManualHonda Accord: Rocker Arm Oil Pressure Switch Removal/Installation

All models except PZEV

1. Disconnect the rocker arm oil pressure switch connector (A).

2. Remove the rocker arm oil pressure switch (B).


2. Remove the rocker arm oil pressure switch (B).

3. Install the parts in the reverse order of removal with a new O-ring (C).

    Rocker Arm Oil Control Valve Removal/Installation
    All models except PZEV 1. Remove the strut brace (see page 20-306). 2. Disconnect the rocker arm oil control solenoid connector (A) and the rocker arm oil pressure switch connector (B). 3. Re ...

    Rocker Arm Oil Pressure Switch A Removal/Installation
    PZEV model 1. Remove the rocker arm oil control valve (see page 11-275). 2. Remove rocker arm oil pressure switch A. 3. Install the parts in the reverse order of removal with a new O-ring (B) ...

    See also:

    Refrigerant Recovery
    • Air conditioning refrigerant or lubricant vapor can irritate your eyes, nose, or throat. • Be careful when connecting service equipment. •Do not breathe refrigerant or vapor. ...

    Back-up Light Switch Test
    1. Disconnect the back-up light switch 2P connector (A). 2. Check for continuity between back-up light switch 2P connector terminals No. 1 and No. 2. There should be continuity only when the shif ...

    Alternator FR Signal Circuit Troubleshooting
    1. Start the engine, and let it idle. 2. Monitor the ALTERNATOR in the DATA LIST with the HDS. 3. Check if the indicated percentage varies when the headlight switch is turned on. Does the p ...