Honda Accord: Connecting Rod Bolt Inspection
1. Measure the diameter of each connecting rod bolt at point A and point B.
2. Calculate the difference in diameter between point A and point B.
Point A-”Point B = Difference in Diameter
Difference in Diameter
Specification: 0-”0.1 mm (0-”0.004 in)
3. If the difference in diameter is out of specification, replace the connecting rod bolt.
Piston Installation
If the Crankshaft is Already Installed
1. Set the crankshaft to bottom dead center (BDC) for
each cylinder as its piston is installed.
2. Remove the connecting rod caps, then install the ring
co ...
Crankshaft Installation
Special Tools Required
Driver Handle, 15 x 135L 07749-0010000
Attachment, 24 x 26 mm 07746-0010700
Oil Seal Driver Attachment, 96 mm 07ZAD-PNAA100
1. M/T model: Install the crankshaft end bushing ...
See also:
Mainshaft Assembly Clearance Inspection
1. Support the bearing Inner race with an appropriate
sized socket ( A ) , and push down on the mainshaft ( B ) .
2. Measure the clearance between 2nd gear (C) and 3rd
gear (D) with a feeler gaug ...
MICU Input Test
NOTE:
• Before testing, troubleshoot the multiplex
integrated control unit first, using B-CAN System Diagnosis Test Mode A
(see page 22-134).
• Before testing, make sure the No. 5 (7. ...
Instrument Panel Brightness
The select/reset knob on the
instrument panel controls the
brightness of the instrument panel
lights. Turn the knob to adjust the
brightness with the ignition switch in
the ON (II) positio ...