Honda Accord: Connecting Rod Bolt Inspection
1. Measure the diameter of each connecting rod bolt at point A and point B.

2. Calculate the difference in diameter between point A and point B.
Point A-”Point B = Difference in Diameter
Difference in Diameter
Specification: 0-”0.1 mm (0-”0.004 in)
3. If the difference in diameter is out of specification, replace the connecting rod bolt.
Piston Installation
If the Crankshaft is Already Installed
1. Set the crankshaft to bottom dead center (BDC) for
each cylinder as its piston is installed.
2. Remove the connecting rod caps, then install the ring
co ...
Crankshaft Installation
Special Tools Required
Driver Handle, 15 x 135L 07749-0010000
Attachment, 24 x 26 mm 07746-0010700
Oil Seal Driver Attachment, 96 mm 07ZAD-PNAA100
1. M/T model: Install the crankshaft end bushing ...
See also:
DTC Troubleshooting
DTC U0155: Immobilizer-keyless Control Unit
Lost Communication With Gauge Control
Module
NOTE: If you are troubleshooting multiple DTCs, be sure
to follow the instructions in B-CAN System Diagnosi ...
Rocker Arm Oil Pressure Switch A
Removal/Installation
PZEV model
1. Remove the rocker arm oil control valve (see page
11-275).
2. Remove rocker arm oil pressure switch A.
3. Install the parts in the reverse order of removal with a
new O-ring (B) ...
Shift Lock Solenoid Test
1. Connect the HDS to the DLC (A) located under the
driver's side of the dashboard.
2. Turn the ignition switch to ON (II). Make sure the HDS
communicates with the PCM. If it does not, go to the
...