Honda Accord: Change Lever Clearance Inspection
1. Measure the clearance between the change lever (A) and the select lever (B) with a feeler gauge (C). If the clearance exceeds the service limit, go to step 2.
Standard: 0.05-”0.25 mm (0.002-”0.010 in)
Service Limit: 0.50 mm (0.020 in)
2. Measure the groove width of the change lever.
- If the groove width is not within the standard, replace the change lever.
- If the groove width is within the standard, replace the select lever.
Standard: 15.00-15.10 mm (0.591-0.594 in)
Reverse Shift Fork Clearance Inspection
1. Measure the clearance between the reverse Idler gear
(A) and the reverse shift fork (B) with a feeler gauge
(C). If the clearance exceeds the service limit, go to
step 2.
Standard; 0.20-0.59 mm ...
Change Lever Assembly Disassembly/Reassembly
NOTE: Prior to reassembling, clean all the parts in solvent, dry them, and
apply grease to contact surfaces as shown. Do
not wash the rubber parts with solvent.
...
See also:
Circuit Diagram
...
Oil Pressure Switch Test
1 Disconnect the oil pressure switch connector (A) from
the oil pressure switch (B).
2. Check for continuity between the oil pressure switch
terminal and the engine (ground). There should be
con ...
DOT Tire Quality Grading (U.S. Vehicles)
The tires on your vehicle meet all U.S. Federal Safety Requirements. All
tires are
also graded for treadwear, traction, and temperature performance according to
Department of Transportation (DOT ...