Honda Accord: Mode Control Motor Replacement
1. Remove the blower unit (see page 21-65).
2. Disconnect the 7P connector (A) from the mode control motor (B). Remove the self-tapping screws and the mode control motor from the heater unit.

3. Install the motor in the reverse order of removal.
Make sure the pin on the motor is properly engaged with the linkage. After installation, make sure the motor runs smoothly.
Mode Control Motor Test
'08-09 models with A/T and '10 model
with A/T
NOTE; Before testing the motor, check for HVAC DTCs
(see page 21-9).
1. Disconnect the 7P connector from the mode control
motor.
Incorrectly app ...
Recirculation Control Motor Test
'08-09 models 4-door with A/T and "10 model
with A/T
NOTE: Before testing the motor, check for HVAC DTCs
(see page 21-9).
1. Disconnect the 7P connector from the recirculation
control moto ...
See also:
Fasten and Position the Seat Belts
Insert the latch plate into the buckle,
then tug on the belt to make sure the
belt is securely latched. Check that
the belt is not twisted, because a
twisted belt can cause serious
injuries ...
Control Unit Input Test
NOTE: Before testing, troubleshoot the multiplex integrated control unit
first, using B-CAN System Diagnosis Test Mode
A (see page 22-134).
Driver's MICU
1. Turn the ignition switch to LOCK (0), ...
Recirculation Control Motor Circuit
Troubleshooting
908-09 models 4-door with A/T and '10 model
with AT
1. Check the No. 16 (7.5 A) fuse in the driver's
under-dash fuse/ relay box.
Is the fuse OK?
YES-Go to step 2.
NO-Replace the fuse, and re ...