Honda Accord: Selector Control Shaft Oil Seal
Replacement - Transmission End Cover - Transaxle - Honda Accord MK8 2008-2012 Service ManualHonda Accord: Selector Control Shaft Oil Seal Replacement

Special Tools Required

-Driver Handle, 15 x 135L 07749-0010000

•Attachment 22 x 24 mm 07746-001A800 1. Remove the oil seal (A) from the end cover (B).

2. Install a new oil seal flush to the end cover using the


2. Install a new oil seal flush to the end cover using the driver handle and the 22 x 24 mm attachment.

Selector Centre! Sheft Bearing


    Idler Gear Shaft Bearing Replacement
    Special Tools Required -Adjustable Bearing Puller, 25—40 mm 07736-A01000B •Driver Handle, 15 x 135L 07749-0010000 -Attachment, 52 x 55 mm 07746-0010400 1. Remove the idler gear shaft be ...

    Selector Centre! Sheft Bearing Replacement
    Special Tools Required •Driver Handle, 15 x 135L 07749-0010000 -Attachment, 22 x 24 mm 07746-001A800 1. Remove the oil seal from the end cover, then remove the bearing. 2. Install a new be ...

    See also:

    Synchronized Mode
    You can set the temperature synchronously for the driver side and the passenger side in synchronized mode. 1. Press the SYNC button.  - The system will switch to the synchronized mode. ...

    Oil Pump Chain Replacement
    NOTE: Keep the oil pump chain away from magnetic fields. Removal 1. Remove the drive belt (see page 4-30). 2. Remove the oil pan (see page 7-11). 3. Support the engine with a jack and a wood ...

    Oil Pump Chain inspection
    1. Remove the oil pan (see page 7-11). 2. Measure the oil pump chain auto-tensioner rod length. If the length is over the service limit, replace the oil pump chain (see page 8-25). Oil Pump Chai ...