Honda Accord: Selector Control Shaft Oil Seal
Replacement - Torque Converter Housing - Transaxle - Honda Accord MK8 2008-2012 Service ManualHonda Accord: Selector Control Shaft Oil Seal Replacement

Special Tools Required

-Driver Handle, 15 x 135L 07749-0010000

-Oil Seal Driver Attachment 07947-ZV00100

1. Remove the oil seal (A) from the torque converter housing (B).

2. Install a new oil seal (A) in the torque converter


2. Install a new oil seal (A) in the torque converter housing to a depth (B) of 0.5-1.5 mm (0.02-0.06 in) below the torque converter housing surface using the driver handle and the oil seal driver attachment.

Shafts and Clutches


    Secondary Shaft Bearing Replacement
    Special Tools Required •Driver Handle, 15 x 135L 07749-0010000 •Attachment, 62 x 68 mm 07746-0010500 1. Remove the set plate bolt, then remove the lock washer (A) and the bearing set pla ...

    Shafts and Clutches
    ...

    See also:

    A/C Signal Circuit Troubleshooting
    NOTE: • If the blower motor does not run at all speeds, the A/C compressor will be inoperative. Run the self-diagnostic function, and check for DTC B1241. Before performing any other troubl ...

    General Troubleshooting Information
    General Operation Refer to the navigation system manual for the navigation system operating procedures. Anti-theft Feature The navigation system and audio unit have a coded theft protection circu ...

    Synchro Sleeve and Hub Inspection and Reassembly
    1. Inspect the gear teeth on all synchro hubs and synchro sleeves for wear (rounded off corners). 2. Install each synchro hub (A) in its mating synchro sleeve (B), and check for free movement. Ma ...