Honda Accord: Recirculation Control Motor
Replacement - Heating/Air Conditioning - Heating, Ventilation, and Air Conditioning - Honda Accord MK8 2008-2012 Service ManualHonda Accord: Recirculation Control Motor Replacement

1. Remove the glove box (see page 20-174).

2. Disconnect the 7P connector (A) from the recirculation control motor (B). Remove the self-tapping screws and the recirculation control motor from the heater unit

3. Install the motor in the reverse order of removal.


3. Install the motor in the reverse order of removal.

Make sure the pin on the motor is properly engaged with the linkage. After installation, make sure the motor runs smoothly.

    Recirculation Control Motor Test
    '08-09 models 4-door with A/T and "10 model with A/T NOTE: Before testing the motor, check for HVAC DTCs (see page 21-9). 1. Disconnect the 7P connector from the recirculation control moto ...

    HVAC Control Unit Removal / Installation
    1. Remove the audio unit (see page 23-115).' 2. Remove the self-tapping screws. If necessary, replace the bulbs (A). 3. While holding the HVAC control unit (A), firmly press the center of one of ...

    See also:

    Side Sill Protection Tape Replacement
    2-door 1. Slowly remove the old side sill protection tape. 2. Clean the body bonding surface with a shop towel dampened in isopropyl alcohol. After cleaning, keep oil, grease, and water from get ...

    Inspection
    Out of Vehicle For front seat belt retractors with seat belt tensioners, review the SRS component locations, 2-door (see page 24-23), 4-door (see page 24-21) and the precautions and procedures (se ...

    Connecting Rod Bolt Inspection
    1. Measure the diameter of each connecting rod bolt at point A and point B. 2. Calculate the difference in diameter between point A and point B. Point A-”Point B = Difference in Diameter D ...