Honda Accord: Recirculation Control Motor
Replacement - Heating/Air Conditioning - Heating, Ventilation, and Air Conditioning - Honda Accord MK8 2008-2012 Service ManualHonda Accord: Recirculation Control Motor Replacement

1. Remove the glove box (see page 20-174).

2. Disconnect the 7P connector (A) from the recirculation control motor (B). Remove the self-tapping screws and the recirculation control motor from the heater unit

3. Install the motor in the reverse order of removal.


3. Install the motor in the reverse order of removal.

Make sure the pin on the motor is properly engaged with the linkage. After installation, make sure the motor runs smoothly.

    Recirculation Control Motor Test
    '08-09 models 4-door with A/T and "10 model with A/T NOTE: Before testing the motor, check for HVAC DTCs (see page 21-9). 1. Disconnect the 7P connector from the recirculation control moto ...

    HVAC Control Unit Removal / Installation
    1. Remove the audio unit (see page 23-115).' 2. Remove the self-tapping screws. If necessary, replace the bulbs (A). 3. While holding the HVAC control unit (A), firmly press the center of one of ...

    See also:

    Airbag System Components
    Airbag System Components Your airbag system includes: Two SRS (supplemental restraint system) front airbags. The driver’s airbag is stored in the center of the steering wheel; the front ...

    Safety When Performing Maintenance
    Some of the most important safety precautions are given here. However, we cannot warn you of every conceivable hazard that can arise in performing maintenance. Only you can decide whether or not ...

    CKP Pulse Plate Replacement
    1. Remove the crankshaft from the engine block (see page 7-14). 2. Remove the CKP pulse plate (A) from the crankshaft. 3. Install the CKP pulse plate in the reverse order of removal. ...