Honda Accord: Recirculation Control Motor
Replacement - Heating/Air Conditioning - Heating, Ventilation, and Air Conditioning - Honda Accord MK8 2008-2012 Service ManualHonda Accord: Recirculation Control Motor Replacement

1. Remove the glove box (see page 20-174).

2. Disconnect the 7P connector (A) from the recirculation control motor (B). Remove the self-tapping screws and the recirculation control motor from the heater unit

3. Install the motor in the reverse order of removal.


3. Install the motor in the reverse order of removal.

Make sure the pin on the motor is properly engaged with the linkage. After installation, make sure the motor runs smoothly.

    Recirculation Control Motor Test
    '08-09 models 4-door with A/T and "10 model with A/T NOTE: Before testing the motor, check for HVAC DTCs (see page 21-9). 1. Disconnect the 7P connector from the recirculation control moto ...

    HVAC Control Unit Removal / Installation
    1. Remove the audio unit (see page 23-115).' 2. Remove the self-tapping screws. If necessary, replace the bulbs (A). 3. While holding the HVAC control unit (A), firmly press the center of one of ...

    See also:

    DTC Troubleshooting
    DTC B1077: Windshield Wiper Auto-stop (AS) Signal Circuit Malfunction NOTE: If you are troubleshooting multiple DTCs, be sure to follow the instructions in B-CAN System Diagnosis Test Mode A (see ...

    Middle Crossmember Gusset Replacement
    2-door NOTE: Take care not to scratch the body. 1. Remove the rear side trim panel (see page 20-127). 2. Pull back the rear part of the carpet as needed. 3. Remove the bolts (A, B), then rem ...