Honda Accord: CMP Sensor B Replacement
1. Disconnect the connector (A) and hoses (B) from the EVAP canister purge valve (C), then remove the EVAP canister purge valve assembly.

2. Disconnect the CMP sensor B connector (A).

3. Remove CMP sensor B (B).
4. Install the parts in the reverse order of removal with a new O-ring (C).
Secondary H02S Replacement
Special Tools Required
02 Sensor Wrench Snap-on S6176 or equivalent,
commercially available
1. Disconnect the secondary H02S 4P connector (A),
then remove the secondary H02S (B).
2. Install the ...
CKP Sensor Replacement
1. Raise the vehicle on a lift.
NOTE: Make sure the vehicle is level, because engine
oil will drip out when you remove the sensor.
2. Remove the CKP sensor cover (A).
3. Disconnect the CKP s ...
See also:
Refrigerant Leak Check
Special Tools Required
• Leak Detector YGK-H-10PM*
• Leak Detector HLD-100*
• Leak Detector TIFZX-1*
• OPTIMAX Jr. A/C Leak Detection Kit TRP124893*
*Available through the Hon ...
Component Location Index
2-door
4-door
...
Air Mix Control Motor Replacement
1. Remove the driver's dashboard undercover (see page
20-170).
2. Disconnect the 7P connector (A) from the air mix
control motor (B). Remove the self-tapping screws
and the air mix control motor ...