Honda Accord: CMP Sensor B Replacement
1. Disconnect the connector (A) and hoses (B) from the EVAP canister purge valve (C), then remove the EVAP canister purge valve assembly.

2. Disconnect the CMP sensor B connector (A).

3. Remove CMP sensor B (B).
4. Install the parts in the reverse order of removal with a new O-ring (C).
Secondary H02S Replacement
Special Tools Required
02 Sensor Wrench Snap-on S6176 or equivalent,
commercially available
1. Disconnect the secondary H02S 4P connector (A),
then remove the secondary H02S (B).
2. Install the ...
CKP Sensor Replacement
1. Raise the vehicle on a lift.
NOTE: Make sure the vehicle is level, because engine
oil will drip out when you remove the sensor.
2. Remove the CKP sensor cover (A).
3. Disconnect the CKP s ...
See also:
Synchro Ring and Gear Inspection
1. Inspect the synchro rings for scoring, cracks, and
damage (A).
Example of synchro ring teeth
2. Inspect the inside of each synchro ring (B) for wear.
Inspect the ...
Voice Control Switch Test
1. Remove the voice control switch (see page 17-7).
2. Measure the resistance between terminals No. 2 and
No. 4 in each switch position according to the table.
3. If the resistance is not as sp ...
Component Location Index
'10 model
With navigation