Honda Accord: CMP Sensor B Replacement
1. Disconnect the connector (A) and hoses (B) from the EVAP canister purge valve (C), then remove the EVAP canister purge valve assembly.

2. Disconnect the CMP sensor B connector (A).

3. Remove CMP sensor B (B).
4. Install the parts in the reverse order of removal with a new O-ring (C).
Secondary H02S Replacement
Special Tools Required
02 Sensor Wrench Snap-on S6176 or equivalent,
commercially available
1. Disconnect the secondary H02S 4P connector (A),
then remove the secondary H02S (B).
2. Install the ...
CKP Sensor Replacement
1. Raise the vehicle on a lift.
NOTE: Make sure the vehicle is level, because engine
oil will drip out when you remove the sensor.
2. Remove the CKP sensor cover (A).
3. Disconnect the CKP s ...
See also:
Starter System Circuit
Troubleshooting
Alternator, Regulator, Battery and Starter OTC3131 *
- Available through the Honda Tool and Equipment
Program 888-424-6857
NOTE:
- Air temperature must be within 59-”100 В°F (15-” ...
Power Window Master Switch Input
Test
NOTE: Before testing, troubleshoot the multiplex Integrated control unit
first, using B-CAN System Diagnosis Test Mode
A (see page 22-134).
1. Turn the ignition switch to LOCK (0), open and clos ...
Parking Brake Cable Replacement
Exploded View
NOTE:
- The parking brake cables must not be bent or
distorted. This will lead to stiff operation and
premature cable failure.
- Refer to the Exploded View as needed during this ...