Honda Accord: CMP Sensor B Replacement - PGM-FI System - Fuel and Emissions - Honda Accord MK8 2008-2012 Service ManualHonda Accord: CMP Sensor B Replacement

1. Disconnect the connector (A) and hoses (B) from the EVAP canister purge valve (C), then remove the EVAP canister purge valve assembly.

2. Disconnect the CMP sensor B connector (A).


2. Disconnect the CMP sensor B connector (A).

3. Remove CMP sensor B (B).


3. Remove CMP sensor B (B).

4. Install the parts in the reverse order of removal with a new O-ring (C).

    Secondary H02S Replacement
    Special Tools Required 02 Sensor Wrench Snap-on S6176 or equivalent, commercially available 1. Disconnect the secondary H02S 4P connector (A), then remove the secondary H02S (B). 2. Install the ...

    CKP Sensor Replacement
    1. Raise the vehicle on a lift. NOTE: Make sure the vehicle is level, because engine oil will drip out when you remove the sensor. 2. Remove the CKP sensor cover (A). 3. Disconnect the CKP s ...

    See also:

    Selector Control Shaft Oil Seal Replacement
    Special Tools Required -Driver Handle, 15 x 135L 07749-0010000 •Attachment 22 x 24 mm 07746-001A800 1. Remove the oil seal (A) from the end cover (B). 2. Install a new oil seal flush to the ...

    DTC Troubleshooting
    PTC 11 -1x { " x " can be 0 ,2 thru 3 or A thru F): Open io the Driver's Airbag First Inflator DTC 11-4x ("x" can be 0,2 thru 9 or A thru F): Open in the Driver's Airbag Second ...