Honda Accord: A/C Signal Circuit Troubleshooting
NOTE: • If the blower motor does not run at all speeds, the A/C compressor will be inoperative. Run the self-diagnostic function, and check for DTC 12. Before performing any other troubleshooting, repair the cause of the inoperative blower motor.
• Do not use this troubleshooting procedure if any of the following items are operative: The condenser fan, the radiator fan, or the A/C compressor, or if the heater is inoperative. Refer to the symptom troubleshooting index.
• Before doing symptom troubleshooting, check for powertrain DTCs (see page 11-3).AIso check for B-CAN codes.
1. Turn the ignition switch to ON (II).
2. Chek if the blower motor operates at all speede.
Does the blower motor operate at all speeds? YES
-Go to step 3.
NO
-Repair the problem in the blower motor circuit (see page21-38).
3. Turn the ignition switch to LOCK (0).
4. Disconnect the HVAC control unit 24P connector.
5. Turn the ignition switch to ON (II).
6. Measure the voltage between HVAC control unit 24P connector terminal No. 21 and body ground.
HVAC CONTROL UNIT 24P CONNECTOR

Wire side of female terminals
Is there battery voltage? YES
-Go to step 8.
NO
-Go to step 7.
7. Measure the voltage between driver's under-dash fuse/relay box connector F (33P) terminal No. 5 and body ground.
DRIVER'S UNDER-DASH FUSE/RELAY BOX CONNECTOR F (33P)

Wire side of female terminals
Is there battery voltage? YES
-Repair an open in the wire between the HVAC control unit and the MICU.
NO-
Check for loose wire or poor connections at driver's under-dash fuse/relay box connector F (33P) terminal No. 5. If the connections are good, substitute a known-good MICU and recheck. If the symptom goes away, replace the original MlCU.
8. Turn the ignition switch to LOCK (0).
9. Measure the evaporator temperature sensor resistance between HVAC control unit 24P connector terminals No. 14 and No. 15.
HVAC CONTROL UNIT 24P CONNECTOR

Wire side of female terminals
Is resistance less than 24 kO? YES
-Check for loose wires or poor connections at the HVAC control unit 24P connector. If the connections are good, substitute a known-good HVAC control unit and recheck. If the symptom goes away, replace the original HVAC control unit.
NO
-Test the evaporator temperature sensor (see page21-58).
A/C Pressure Switch Circuit
Troubleshooting
NOTE:
• Do not use this troubleshooting procedure if any of the
following items are operative: The condenser fan, the
radiator fan, or the A/C compressor, or if the heater is
inoperative. Ref ...
Evaporator Temperature Sensor Test
NOTE: Before testing the sensor, check for HVAC DTCs
(see page 2 1 - 9).
1. Remove the evaporator temperature sensor (see
page 21-67).
2. Dip the sensor in ice water, and measure the
resistan ...
See also:
B-CAN System Diagnosis Test Mode
C
Do this diagnosis if a component that is controlled by the
B-CAN system does not stop or turn off.
NOTE:
• If the component does not turn on, go to B-CAN
System Diagnosis Test Mode D {see p ...
Sunshade Replacement
1. Remove the drain channel (see page 20-94).
2. Slide the sunshade (A) until you can see both
sunshade slider spacers (B).
3. Remove the screws, then remove both sunshade
slider spacers.
4. ...
In-car Temperature Sensor
Replacement
1. Remove the driver's inner dashboard trim (see page
20-167).
2. Disconnect the connector (A), and remove the in-car
temperature sensor (B) from the air hose (C).
3. Install the sensor in the ...